Heat Resistant Paint

Heat Resistant Paint

One pack, dry at room or higher temperature.On surface likely to reach up to 300~600℃

Product Details


Heat Resistant Paint
















Product Information

Volume Solids

40%±2%

Finish/Sheen

Gloss

Typical Film Thickness

30microns dry (75microns wet)

Theoretical Coverage

13.3m2/L at typical film thickness

Mix Ratio

One pack

Method of Application

 

 

Airless Spray

Recommended

 

Tip size range

 

0.38-0.53mm

 

 

 

Output pressure

 

≥17MPa

Air Spray

 

Tip size range

 

2.0-3.0mm

 

 

Output pressure

 

≥0.4MPa

 

Brush/Roller

For small area only

 

Thinner

Not recommended. Use only in exceptional circumstances (volume 5%)

 

Cleaner

 

JX-601

Induction Period

Not applicable

Drying Information

 

10

25

35

Touch Dry

1h

30min

20min

Hard Dry

8h

6h

3h

Pot Life

Not applicable

Overcoating Data       Substrate Temperature

Overcoated by

10

25

35

Min Max

Min Max

Min Max

725-W61-22

8h 

6h 

3h 

Storage

Store in cool and dry conditions. Well ventilate. Keep away from hot and fire. Shelf Life: 12 months minimum at 25. Subject to re-inspection thereafter.

Pack Size

21.6kg/18L in 20L container

Flash Point

Greater than 28

Systems and

Compatibility

Consult your Sunrui Representative for the systems best suited for the surfaces to be protected.

Surface Preparation

All surfaces to be coated should be clean, dry and free from contamination.

Abrasive Blast Cleaning

Abrasive blast clean to Sa2½GB/T8923.1-2011. If oxidation has occurred between blasting and application of 725-W61-22, the surface should be reblasted to the specified visual standard.

Surface defects revealed by the blast cleaning process should be ground. Filled, ortreated in the appropriate manner.

Repair

The areas to be repaired should be cleaned to St3GB/T 8923.1-2011by  mechanical method or higher level of surface prepared to Sa2.5GB/T 8923.1-2011by abrasive blasting. Abrade the area immediately surrounding the repair to provide a key for subsequent coating application. Overlap areas should be kept to a minimum.

Limitations

Apply in good weather. Temperature of the surface to be coated must be least 3 above the dew point when the humidity is lower than 85%.

The dry time and overcoating interval may change according to the environment factors.

Avoiding absorb the solvent steam and paint steam for long time. Skin and eyes must avoid contacting the paint. Pay attention to ventilate and fireproof when applying.

 

 

Duty statement

The data in the sheet base on the information from the laboratory and practice. The application may exceed the control, so we only ensure our product quality. We own the right of the data sheet modification without informing.



Inquiry