725-H06-10 Wet-surface epoxy sealing coating-Light yellow
Product Description
--A transparent epoxy surface sealer with good penetration properties.
--It can tolerate wet surface.
--VOC less than 420g/L
Intended Uses
--For prepared wet concrete substrates.
--For use on concrete surface of offshore facilities.
Product Information
Volume Solids
95%±2%
Finish/Sheen
Matt
Typical Film Thickness
50microns dry (52microns wet)
Theoretical Coverage
1.9m2/L at typical film thickness
Mix Ratio
2.6:1(volume)2.8:1(weight)
Method of Application
Airless Spray
Recommended
Tip size range
0.38-0.53mm
Output pressure
≥15MPa
Air Spray
Tip size range
2.0-3.0mm
Output pressure
≥0.4MPa
Brush/Roller
For small area only
Thinner
Not recommended. Use only in exceptional circumstances (volume 5%)
Cleaner
HX-501
Induction Period
Not necessary
Drying Information
15℃
25℃
35℃
Touch Dry
2h
1.5h
45min
Hard Dry
24h
16h
12h
Pot Life
1.5h
1h
30min
Overcoating Data Substrate Temperature
Overcoated by
15℃
25℃
35℃
Min Max
Min Max
Min Max
725-H45-ZF101
20h 10d
16h 7d
12h 5d
725-H45-ZF101G
20h 10d
16h 7d
12h 5d
725-H53-38
20h 10d
16h 7d
12h 5d
Storage
Store in cool and dry conditions. Well ventilate. Keep away from hot and fire. Shelf Life: 12 months minimum at 25℃. Subject to re-inspection thereafter.
Pack Size
Part A
15.1kg/14.5L in 20 L container
Part B
5.3kg/5.5L in 6L container
Flash Point
Part A
Greater than 31℃
Part B
Greater than 31℃
Mixed paint
Greater than 31℃
Surface Preparation
All surfaces to be coated should be clean, dryand free from contamination.
Concrete surface
Pre-clean all surfaces by brooming and if necessary accomplished by scrubbing with heavy duty cleaner / degreaser or low pressure water cleaning or chemical washing to remove oils, grease, wax, fatty acids and other contaminations.
Removal of surface laitance, curing compound and creation of surface profile can be accomplished by grinding with a selection of hand tools or electrical equipment.
Limitations
This product will not cure adequately below 5℃. For maximum performance ambient curing temperature should be above 10℃。
Apply in good weather when the humidity is lower than 85%.The concrete surface must be wiped without visible water.
Before overcoating 725-H06-10, it must be clean and dry.
The dry time and overcoating interval may change according to the environment factors.
Avoiding absorb the solvent steam and paint steam for long time. Skin and eyes must avoid contacting the paint. Pay attention to ventilate and fireproof when applying.
Duty statement
The data in the sheet base on the information from the laboratory and practice. The application may exceed the control, so we only ensure our product quality. We own the right of the data sheet modification without informing.